OEM-/Originalnummer: | FF01-438/509/578-25 |
---|---|
Transmission Band 1: | Tavg > 93% 426 - 450 nm |
Center Wavelength 1: | 438 nm |
FWHM Bandwidth 1 (nominal): | 28.8 nm |
Blocking Band 1: | ODavg > 5 200 - 300 nm |
Transmission Band 2: | Tavg > 93% 497.6 - 519.5 nm |
Guaranteed Minimum Bandwidth 1: | 24 nm |
Center Wavelength 2: | 509 nm |
Guaranteed Minimum Bandwidth 2: | 21.9 nm |
FWHM Bandwidth 2 (nominal): | 25.5 nm |
Blocking Band 2: | ODavg > 6 300 - 421.1 nm |
Transmission Band 3: | Tavg > 93% 567.4 - 588.6 nm |
Center Wavelength 3: | 578 nm |
Guaranteed Minimum Bandwidth 3: | 21.2 nm |
FWHM Bandwidth 3 (nominal): | 25.2 nm |
Blocking Band 3: | OD > 3.5 458.5 nm |
Blocking Band 4: |
ODavg > 8 464 - 486 nm Design specification measurements are noise-floor limited |
Blocking Band 5: | OD > 3.5 491.8 nm |
Blocking Band 6: | OD > 3.5 525.8 nm |
Blocking Band 7: |
ODavg > 8 532 - 554 nm Design specification measurements are noise-floor limited |
Blocking Band 8: | OD > 3.5 560.7 nm |
Blocking Band 9: | OD > 3.5 595.8 nm |
Blocking Band 10: |
ODavg > 8 603 - 800 nm Design specification measurements are noise-floor limited |
Angle of Incidence: | 0 ± 5 degrees |
Cone Half-angle: | 7 degrees |
Optical Damage Rating: | Testing has proven to show no signs of degradation when exposed to at least 6.0 W of power from an unfiltered xenon arc lamp over a 25 mm diameter (corresponding to 1.2 W/cm2) for over 500 hrs. |
Filter Effective Index: |
1.90 Understanding `Effective Index of Refraction` neff |
Substrate type: | low-autofluorescence optical quality glass |
Transverse Dimensions (Diameter: | 25 mm |
Transverse Tolerance: | + 0.0 / - 0.1 mm |
Filter Thickness (mounted): | 5.0 mm |
Filter Thickness Tolerance (mou: | ± 0.1 mm |
Clear Aperture: | ≥ 21 mm |
Scratch-Dig: | 60-40 |
Substrate thickness: | 2.0 mm |
Orientation: | Arrow on ring indicates preferred direction of propagation of light |
Other physical specs: | Standard Specifications of Our Filters and Beam Splitters |
Abmessungen: | D = 25 mm |
Anzahl Bänder/Kanten/Notch: | 3 |
Art des Filters: | Multiband |
Anwendung (Filter): | Standard/Fluoreszenz |
Substratdicke: | 2,0 mm |
Scratch-Dig: | 60-40 |
freie Apertur: | >= 21 mm |